PRODUCTS
- Show all
- Line Interactive UPS
- Online 1Ph / 1Ph UPS
- Online 3Ph / 1Ph UPS
- Online 3Ph / 3Ph UPS
- Modular UPS
- Show all
- 1Ph / 2 Poles STS
- 3Ph / 3-4 Poles STS
- Show all
- 1Ph / 2 Poles STS
- 3Ph / 3-4 Poles STS
- Show all
- 1Ph AVR
- 3Ph AVR
- Show all
- Hybrid UPS
- Solar Converter
- Solar Direct Drive
- Solar Panel
- Solar Inverter
DS POWER X UPS SERIES
3/3 Uninterruptible Power Supplies
100kVA - 400kVA
• Transformerless UPS topology
• 3 Level rectifier and inverter
• High input power factor
• High efficiency up to 96.0%
• Cold start function
• Static and maintenance by-pass switch
• Output short circuit and overload protection
• External REPO switch input
• 512 events memory (512 events 45000 alarms)
• Clock and calender (battery supported)
• Automatic battery test,remaining battery time indicator
• Temperature compansated charge system (optional)
• 2 RS232 serial ports and 12 dry contact outputs
• 3 DSP controlled modular structure
• Optional SNMP and MODBUS adaptors
• Optional graphical panel
• Optional usb flash memory
• Full digital structure
• Small footprint
• Ecomode operation (optional)
• Fewer electronic components
• Output current limiting
• Advanced diagnostics for the input
• Selectable input/output voltage/frequency/range
• Split by-pass input (second input)
• Output DC leakage protection
• Separate DSP for inverter control
• Separate DSP for the PFC
• 3 level battery protection
• High charge current capacity
• Charge/discharge current indicator
• Advanced remote control features
• Manufactured according to EC Directive; EN62040
• 2 years warranty
• 10 years spare parts support
MODEL |
DX3100 |
DX3120 |
DX3160 |
DX3200 |
DX3250 |
DX3300 |
DX3400 |
Rated Power |
100 |
120 |
160 |
200 |
250 |
300 |
400 |
By-pass voltage |
380/400 VAC 3 Phase + N, ± 10 (adjustable) |
||||||
Frequency range |
50Hz / 60Hz, ± 5% |
||||||
OUTPUT |
|||||||
Voltage |
380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
||||||
Frequency |
50Hz / 60Hz |
||||||
Frequency tolerance |
Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
||||||
Overload protection |
at 100% - 125% load : 10 min. - at 125% - 150% load :1 min. - > at 150% load : by-pass |
||||||
Current Crest Ratio |
3:1 |
||||||
Effiency |
up to 95.5% |
up to 96% |
|||||
BATTERY |
|||||||
Battery type |
VRLA AGM / GEL / NiCd |
||||||
Nominal voltage |
± 360 VDC |
||||||
Battery test |
Standard every 72 hours (adjustable) |
||||||
OPTIONS |
|||||||
Software |
T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 10-50-100-200 clients |
||||||
PHYSICS CHARACTERISTIC |
|||||||
Dimensions (mm) HxWxD |
1440x475x890 |
1900x880x775 |
1900x1250x775 |
||||
ENVIRONMENT |
|||||||
Relative humidity |
< 90% max. (non-condensing) |
||||||
Acoustic noise |
< 62 dBA |
< 65 dBA |
< 67 dBA |